Panel or Subplate Mounted Pneumatic Timer (Up to 3 Minutes)Item # PMT1J3B2

The Type PMT timer is an adjustable precise time delay control device. The timer is available with an on delay (NC) logic output.

Timing operation is dependent upon the input of a separate control signal which starts the timing sequence by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.

The PMT has a separate subplate enabling the unit to be supplied with 10-32 or 1/8 NPT porting. The timer can be panel mounted with a bezel, or in the rear on a sub plate.

Item #PMT1J3B2
TypePanel Mount Horizontal Bezel
Timing Range18 to 180 sec.
Operating Pressure Range15 to 100 psi
Connections10-32 or 1/8 NPT ports via bottom sub plate
Control Pressure(A) Low Press. - 15 to 100PSI
(B) Standard - 30 to 100 psi
MediaFiltered air or non-aggressive gas, non-lubricated.
Timing ValveCv - 0.005
Flow at 100 psi -0.1 CFM
Dial IndicatorDisplays set time
Timing StartApplication of pilot pressure to control port
ResetAutomatic by removal of pilot signal.
Reset Time60 ms at 50 psi
Repeatability± 3% of selected time
Time SettingVia Adjustment Knob
Accuracy ±10%
OperationTiming cycle uses atmospheric pressure drawn into vacuum.
Air Consumption0.1 CFM at 100 psi
MaterialsAcetal and polycarbonate enclosure
Diaphragms - Buna N
Operating Ambient0 to 65 ºC
32 to 150 ºF
Height2 1/16 in.
Width1 1/2 in.
Depth4 1/4 in.
MountingVia sub plate (2 holes) or if Panel mounted, through a 1 1/2" square cutout. 2 mounting holes required, hardware included.
Low Pressure VersionThe PMT standard control input pressure range is 30 to 100 PSI. For a low pressure pilot actuator (15 PSI min.), change the "B" in the catalog number to "A".
Subplate Mounting PositionStandard timers are supplied with the subplatemounting position at the bottom of the timer. Formounting the subplate in another position, change thelast digit of the catalog number as follows: 1 for top; 2for right side; 3 for bottom; 4 for left side.
Power ConnectionsFor installations requiring larger output valves, use thestandard timer and connect a pneumatically operatedsingle air piloted 3 or 4 way valve of the size required tothe timer output. Contact factory with sizerequirements.
Typical CircuitsSee typical timing circuit diagrams at the end of the timer catalog section for help in constructing pneumatic timer circuits.