1-800-221-0714
Flush Head Pushbutton, 1/8 PortsItem # 75023-62-44
Flush Head pushbuttons are used to prevent accidental operation or provide flat panel appearance. Button is flush with shroud surface and diameter is 1-3/8 inch.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole is 1 3/16 inch (30 mm) diameter. Above panel dimensions are 1.375" Dia. x 0.875" H. (Mushroom) or 0.375" H. (Flush Head).
Behind panel dimensions of 3 way valve - 3.25" D x 1.375" H x 0.75" W; 4 way valve- 4" D x 1.375" H x 75" W. Allow space for fittings and tubing.
Valve through body mounting holes are 3/16" diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole is 1 3/16 inch (30 mm) diameter. Above panel dimensions are 1.375" Dia. x 0.875" H. (Mushroom) or 0.375" H. (Flush Head).
Behind panel dimensions of 3 way valve - 3.25" D x 1.375" H x 0.75" W; 4 way valve- 4" D x 1.375" H x 75" W. Allow space for fittings and tubing.
Valve through body mounting holes are 3/16" diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # | 75023-62-44 |
Description | 4 Way Spring Return |
Port Type | 1/8 NPT Ports (USA Std.) |
Orifice | 0.236 in. 6 mm |
Body No. | 1S |
Color | Green |
Panel Dia. | 1.375 in. |
Panel Height | 0.375 in. |
Behind Panel Depth | 4 in. |
Behind Panel Height | 1.375 in. |
Behind Panel Width | 0.75 in. |
Panel Mounting Hole | 1 3/16 in. 30 mm |
Operating Pressure Range | 0 to 145 psi |
Actuation Force @ 90 PSI | Approx. 7.9 lbs. |
Cv | 0.68 |
Kv | 9.7 |
Flow @ 45 PSI | 17.6 SCFM |
Flow @ 90 PSI | 31.7 SCFM |
Flow @ 145 PSI | 51.5 SCFM |
Flow @ 3 Bar | 500 lpm |
Flow @ 6 Bar | 900 lpm |
Flow @ 10 Bar | 1460 lpm |
Intended Use- Series 75 and 76 valves are intended for general purpose industrial applications utilizing normal shop air supply systems. For special applications with other media or other environments, contact Kuhnke.
Media- Compressed air or other neutral gases, properly filtered. For applications on liquids contact Kuhnke.
Lubrication- Valves operate on lubricated or non-lubricated systems. After using components in a lubricated system, do not switch to an un lubricated system. Avoid over lubrication.
Vacuum Applications- Spool Valve designs can be applied on vacuum systems. For applications using poppet valves, use only specially assembled valves shown in the catalog.
Dimensions and Design Changes- All dimensions in this catalog are approximate, if necessary, detailed drawings can be obtained from Kuhnke or from one of the Kuhnke websites. Dimensions, valve design and materials are subject to change without notice.
Metric and NPT threads- Although similar in size, valve port threads in metric ported valves are different from NPT versions. NPT versions have a tapered thread that is used to form a seal with the fitting thread. Metric thread is straight, and the seal is provided by an o-ring or washer normally included with the connection fitting. Metric fittings can be used on NPT threaded valves, but NPT fittings cannot be used on metric threaded valves.
Media- Compressed air or other neutral gases, properly filtered. For applications on liquids contact Kuhnke.
Lubrication- Valves operate on lubricated or non-lubricated systems. After using components in a lubricated system, do not switch to an un lubricated system. Avoid over lubrication.
Vacuum Applications- Spool Valve designs can be applied on vacuum systems. For applications using poppet valves, use only specially assembled valves shown in the catalog.
Dimensions and Design Changes- All dimensions in this catalog are approximate, if necessary, detailed drawings can be obtained from Kuhnke or from one of the Kuhnke websites. Dimensions, valve design and materials are subject to change without notice.
Metric and NPT threads- Although similar in size, valve port threads in metric ported valves are different from NPT versions. NPT versions have a tapered thread that is used to form a seal with the fitting thread. Metric thread is straight, and the seal is provided by an o-ring or washer normally included with the connection fitting. Metric fittings can be used on NPT threaded valves, but NPT fittings cannot be used on metric threaded valves.
- AppendixValve-Specifications.pdf
- Ellis/Kuhnke Controls
132 Lewis Street Unit A-2, Eatontown, N.J. 07724
Phone: 1-800-221-0714
Fax: 732-291-8154
Email: Info@ekci.com
- Home Pneumatic Controls Technical Info CAD Drawings Contact Us Pneumatic Timers Blog Site Map
If you are looking for Pneumatic Controls, Pneumatic Valves then look no further than Ellis/Kuhnke Controls.