1-800-221-0714
Panel Mounted Pneumatic Timer (Up to 100 Hours)Item # 54023
The 54 Series timer is a totally pneumatic device with ± 1% repeatability. Timing is fully adjustable throughout the timing range by a knob on the front dial face. The standard timer is equipped with a special 4 way valve which provides for on or off delay timing (depending on plumbing connections). The front dial displays set time and the time remaining in the cycle.
The operation of the timer depends on the input of a separate control signal. The control signal drives a regulated air motor and gear chain to provide accurate timing regardless of control air pressure fluctuation. The timer resets automatically (approx. 200 ms) after removal of control pressure signal.
A special version of the timer includes a rotor stop option which allows for an external valve to be added to permit a "count down on hold" function.
The 54 Series timer is self-contained in a panel mounted lexan case with a front timing adjustment knob. Connections are made at the rear of the timer. Spring clips are used to panel mount the unit.
The operation of the timer depends on the input of a separate control signal. The control signal drives a regulated air motor and gear chain to provide accurate timing regardless of control air pressure fluctuation. The timer resets automatically (approx. 200 ms) after removal of control pressure signal.
A special version of the timer includes a rotor stop option which allows for an external valve to be added to permit a "count down on hold" function.
The 54 Series timer is self-contained in a panel mounted lexan case with a front timing adjustment knob. Connections are made at the rear of the timer. Spring clips are used to panel mount the unit.
Item # | 54023 |
Type | Standard Timer |
Timing Range | 0.3 to 10 min. |
Operating Pressure Range | 0 to 145 psi |
Control Pressure | 20 to 145 psi non-lubricated air |
Output Valve | 4 way (5 ported) Cv - 0.13 Flow - 7 CFM at 100 psi Orifice size - 2mm |
Connection | 10-32 (M5) ports |
Media | Filtered air or gas. Non-lubricated. |
Indicators | Displays set time and time remaining before valve actuation |
Time Setting | Via front dial knob. Adjustable throughout timing range |
Accuracy of Setting | ± 2% |
Repeatability | ± 1% of end scale value |
Operation | Independent regulated air motor. Air consumption 0.35 CFM. Output air piloted 4 way valve. |
Reset | Automatic - by removal of control pressure. |
Reset Time | 200 ms. |
Timing Sequence | On delay or off delay depending on valve connections. |
Operating Ambient | 0 to +60 ºC 32 to 140 ºF |
Materials | Lexan Case Cast Aluminum Rear Housing Nylon, Brass Stainless Alloy Mechanism |
Faceplate Dimensions | 2 13/16 in² |
Behind Panel Depth | 4 3/8 in. |
Behind Panel Height | 2 5/8 in. |
Behind Panel Width | 2 5/8 in. |
Panel Cutout | 2 5/8 in² |
Mounting | Spring clips |
Port Identification | Port 12 - Control input signal (on timer body). Valve 1 - System air supply 2 - Valve output "off delay connection" 3 - Exhaust for port 2 4 - Valve output "on delay connection" 5 - Exhaust for port 4 |
Replacement Parts | Control port input filter 72754500-00 Output valve 54530 |
Rotor Stop Option (Countdown on Hold) | A rotor stop option is available to override the timing action or to hold the timer valve in its switched position after the timer has completed its cycle, and signal pressure is removed. Option provides 2 additional rear ports connected via tube, which allows valves or other logic devices to be spliced into the internal circuit between the pilot signal regulator and rotor assembly. For holding timer valve in its switched position or to place "timing on hold", an external 3 way valve (NO)can be used to block the flow to the air motor(connected between rotor stop ports 1-2). If timing on hold is desired, the pilot signal must remain on throughout the entire cycle. |
Power Connections | For installations requiring larger valves, use the standard timer and connect a pneumatically operated single air piloted 3 or 4 way valve of the size required to the timer output. Contact factory with size requirements. |
Typical Circuits | See typical timing circuit diagrams at the end of the timer catalog section for help in constructing pneumatic timer circuits. |
Diagrams | Timer output valve is 4 way, 5 ported with 10-32 (M5) connections. Valves are supplied from factory blocked with a cap nut (port 4) for 3 way off delay. For on delay, move cap nut to port 2. For full 4 way operation remove nut. |
- On Delay Blocked Port 2
- Off Delay Blocked Port 4
- CAD DrawingsPneumatic-Timer-54-Series.pdf
- Ellis/Kuhnke Controls
132 Lewis Street Unit A-2, Eatontown, N.J. 07724
Phone: 1-800-221-0714
Fax: 732-291-8154
Email: Info@ekci.com
- Home Pneumatic Controls Technical Info CAD Drawings Contact Us Pneumatic Timers Blog Site Map
If you are looking for Pneumatic Controls, Pneumatic Valves then look no further than Ellis/Kuhnke Controls.