Technical Specifications: 51 Series



Operating Pressure
25 to 145 PSI
Connections
10-32(M5) or 1/8 NPTF ports
Media
Filtered air or nonaggressive gas, non lubricated
Operating Valve
3 way - internal exhaust
Orifice size - 2 mm
Cv - .13
Flow @ 100 PSI -7 CFM
Timing Start
Application of pilot (or Line) pressure to control port 12.
Reset
By removal of pilot (or Line) signal - independent of whether the time interval has elapsed or not.
Reset Time
200 ms
Repeatability
±2% of selected time
Time Setting
Via adjustment knob
Operation
Timing cycle uses atmospheric pressure drawn into vacuum
Air Consumption
During timing cycle only - .1 cfm
Materials
Polyamide housing, aluminum base, Buna N seals
Operating Ambient
-10°C to 60°C (14°F to 140°F)
Mounting
Via 4 holes in Base
Dimensions (inches)
10-32 Port
1/8 Port
Height
3 5/8
4 1/8
Width
1 1/2
2 3/4
Depth
2 3/4
2 3/4
Weight
12 oz
15 oz

ELLIS/KUHNKE CONTROLS
26 West Highland Avenue, Atlantic Highlands, N.J. 07716
1-800-221-0714
Fax: 732-291-8154
E-mail: